#!/usr/bin/python
# -*- coding: utf-8 -*-
#
# Dell EMC OpenManage Ansible Modules
# Version 5.0.1
# Copyright (C) 2021-2022 Dell Inc. or its subsidiaries. All Rights Reserved.
# GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt)
#
from __future__ import (absolute_import, division, print_function)
__metaclass__ = type
DOCUMENTATION = """
---
module: ome_device_local_access_configuration
short_description: Configure local access settings on OpenManage Enterprise Modular.
description: This module allows to configure the local access settings of the power button, quick sync, KVM,
LCD, and chassis direct access on OpenManage Enterprise Modular.
version_added: "4.4.0"
extends_documentation_fragment:
- dellemc.openmanage.omem_auth_options
options:
device_id:
type: int
description:
- The ID of the chassis for which the local access configuration to be updated.
- If the device ID is not specified, this module updates the local access settings for the I(hostname).
- I(device_id) is mutually exclusive with I(device_service_tag).
device_service_tag:
type: str
description:
- The service tag of the chassis for which the local access settings needs to be updated.
- If the device service tag is not specified, this module updates the local access settings for the I(hostname).
- I(device_service_tag) is mutually exclusive with I(device_id).
enable_kvm_access:
type: bool
description: Enables or disables the keyboard, video, and mouse (KVM) interfaces.
enable_chassis_direct_access:
type: bool
description: Enables or disables the access to management consoles such as iDRAC and the management module of
the device on the chassis.
chassis_power_button:
type: dict
description: The settings for the chassis power button.
suboptions:
enable_chassis_power_button:
required: true
type: bool
description:
- Enables or disables the chassis power button.
- If C(False), the chassis cannot be turn on or turn off using the power button.
enable_lcd_override_pin:
type: bool
description:
- Enables or disables the LCD override pin.
- This is required when I(enable_chassis_power_button) is C(False).
disabled_button_lcd_override_pin:
type: int
description:
- The six digit LCD override pin to change the power state of the chassis.
- This is required when I(enable_lcd_override_pin) is C(True).
- The module will always report change when I(disabled_button_lcd_override_pin) is C(True).
quick_sync:
type: dict
description:
- The settings for quick sync.
- The I(quick_sync) options are ignored if the quick sync hardware is not present.
suboptions:
quick_sync_access:
type: str
choices: [READ_WRITE, READ_ONLY, DISABLED]
description:
- Users with administrator privileges can set the following types of I(quick_sync_access).
- C(READ_WRITE) enables writing configuration using quick sync.
- C(READ_ONLY) enables read only access to Wi-Fi and Bluetooth Low Energy(BLE).
- C(DISABLED) disables reading or writing configuration through quick sync.
enable_inactivity_timeout:
type: bool
description: Enables or disables the inactivity timeout.
timeout_limit:
type: int
description:
- Inactivity timeout in seconds or minutes.
- The range is 120 to 3600 in seconds, or 2 to 60 in minutes.
- This option is required when I(enable_inactivity_timeout) is C(True).
timeout_limit_unit:
type: str
choices: [SECONDS, MINUTES]
description:
- Inactivity timeout limit unit.
- C(SECONDS) to set I(timeout_limit) in seconds.
- C(MINUTES) to set I(timeout_limit) in minutes.
- This option is required when I(enable_inactivity_timeout) is C(True).
enable_read_authentication:
type: bool
description: Enables or disables the option to log in using your user credentials and to read the
inventory in a secure data center.
enable_quick_sync_wifi:
type: bool
description: Enables or disables the Wi-Fi communication path to the chassis.
lcd:
type: dict
description:
- The settings for LCD.
- The I(lcd) options are ignored if the LCD hardware is not present in the chassis.
suboptions:
lcd_access:
type: str
choices: [VIEW_AND_MODIFY, VIEW_ONLY, DISABLED]
description:
- Option to configure the quick sync settings using LCD.
- C(VIEW_AND_MODIFY) to set access level to view and modify.
- C(VIEW_ONLY) to set access level to view.
- C(DISABLED) to disable the access.
user_defined:
type: str
description: The text to display on the LCD Home screen. The LCD Home screen is displayed when the system
is reset to factory default settings. The user-defined text can have a maximum of 62 characters.
lcd_language:
type: str
description:
- The language code in which the text on the LCD must be displayed.
- en to set English language.
- fr to set French language.
- de to set German language.
- es to set Spanish language.
- ja to set Japanese language.
- zh to set Chinese language.
requirements:
- "python >= 3.8.6"
author:
- "Felix Stephen (@felixs88)"
notes:
- Run this module from a system that has direct access to OpenManage Enterprise Modular.
- This module supports C(check_mode).
- The module will always report change when I(enable_chassis_power_button) is C(True).
"""
EXAMPLES = """
---
- name: Configure KVM, direct access and power button settings of the chassis using device ID.
dellemc.openmanage.ome_device_local_access_configuration:
hostname: "192.168.0.1"
username: "username"
password: "password"
ca_path: "/path/to/ca_cert.pem"
device_id: 25011
enable_kvm_access: true
enable_chassis_direct_access: false
chassis_power_button:
enable_chassis_power_button: false
enable_lcd_override_pin: true
disabled_button_lcd_override_pin: 123456
- name: Configure Quick sync and LCD settings of the chassis using device service tag.
dellemc.openmanage.ome_device_local_access_configuration:
hostname: "192.168.0.1"
username: "username"
password: "password"
ca_path: "/path/to/ca_cert.pem"
device_service_tag: GHRT2RL
quick_sync:
quick_sync_access: READ_ONLY
enable_read_authentication: true
enable_quick_sync_wifi: true
enable_inactivity_timeout: true
timeout_limit: 10
timeout_limit_unit: MINUTES
lcd:
lcd_access: VIEW_ONLY
lcd_language: en
user_defined: "LCD Text"
- name: Configure all local access settings of the host chassis.
dellemc.openmanage.ome_device_local_access_configuration:
hostname: "192.168.0.1"
username: "username"
password: "password"
ca_path: "/path/to/ca_cert.pem"
enable_kvm_access: true
enable_chassis_direct_access: false
chassis_power_button:
enable_chassis_power_button: false
enable_lcd_override_pin: true
disabled_button_lcd_override_pin: 123456
quick_sync:
quick_sync_access: READ_WRITE
enable_read_authentication: true
enable_quick_sync_wifi: true
enable_inactivity_timeout: true
timeout_limit: 120
timeout_limit_unit: SECONDS
lcd:
lcd_access: VIEW_MODIFY
lcd_language: en
user_defined: "LCD Text"
"""
RETURN = """
---
msg:
type: str
description: Overall status of the device local access settings.
returned: always
sample: "Successfully updated the local access settings."
location_details:
type: dict
description: returned when local access settings are updated successfully.
returned: success
sample: {
"SettingType": "LocalAccessConfiguration",
"EnableChassisDirect": false,
"EnableChassisPowerButton": false,
"EnableKvmAccess": true,
"EnableLcdOverridePin": false,
"LcdAccess": "VIEW_ONLY",
"LcdCustomString": "LCD Text",
"LcdLanguage": "en",
"LcdOverridePin": "",
"LcdPinLength": null,
"LcdPresence": "Present",
"LedPresence": null,
"QuickSync": {
"EnableInactivityTimeout": true,
"EnableQuickSyncWifi": false,
"EnableReadAuthentication": false,
"QuickSyncAccess": "READ_ONLY",
"QuickSyncHardware": "Present",
"TimeoutLimit": 7,
"TimeoutLimitUnit": "MINUTES"
}
}
error_info:
description: Details of the HTTP Error.
returned: on HTTP error
type: dict
sample: {
"error": {
"code": "Base.1.0.GeneralError",
"message": "A general error has occurred. See ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "GEN1234",
"RelatedProperties": [],
"Message": "Unable to process the request because an error occurred.",
"MessageArgs": [],
"Severity": "Critical",
"Resolution": "Retry the operation. If the issue persists, contact your system administrator."
}
]
}
}
"""
import json
import socket
import copy
from ssl import SSLError
from ansible.module_utils.basic import AnsibleModule
from ansible.module_utils.six.moves.urllib.error import URLError, HTTPError
from ansible.module_utils.urls import ConnectionError
from ansible_collections.dellemc.openmanage.plugins.module_utils.ome import RestOME, ome_auth_params
DOMAIN_URI = "ManagementDomainService/Domains"
DEVICE_URI = "DeviceService/Devices"
LAC_API = "DeviceService/Devices({0})/Settings('LocalAccessConfiguration')"
CONFIG_FAIL_MSG = "one of the following is required: enable_kvm_access, enable_chassis_direct_access, " \
"chassis_power_button, quick_sync, lcd"
DOMAIN_FAIL_MSG = "The operation to configure the local access is supported only on " \
"OpenManage Enterprise Modular."
FETCH_FAIL_MSG = "Unable to retrieve the device information."
DEVICE_FAIL_MSG = "Unable to complete the operation because the entered target device {0} '{1}' is invalid."
LAC_FAIL_MSG = "Unable to complete the operation because the local access configuration settings " \
"are not supported on the specified device."
CHANGES_FOUND = "Changes found to be applied."
NO_CHANGES_FOUND = "No changes found to be applied."
SUCCESS_MSG = "Successfully updated the local access settings."
def get_ip_from_host(hostname):
ipaddr = hostname
try:
result = socket.getaddrinfo(hostname, None)
last_element = result[-1]
ip_address = last_element[-1][0]
if ip_address:
ipaddr = ip_address
except socket.gaierror:
ipaddr = hostname
except Exception:
ipaddr = hostname
return ipaddr
def get_chassis_device(module, rest_obj):
key, value = None, None
ipaddress = get_ip_from_host(module.params["hostname"])
resp = rest_obj.invoke_request("GET", DOMAIN_URI)
for data in resp.json_data["value"]:
if ipaddress in data["PublicAddress"]:
key, value = ("Id", data["DeviceId"])
break
else:
module.fail_json(msg=FETCH_FAIL_MSG)
return key, value
def check_domain_service(module, rest_obj):
try:
rest_obj.invoke_request("GET", DOMAIN_URI, api_timeout=5)
except HTTPError as err:
err_message = json.load(err)
if err_message["error"]["@Message.ExtendedInfo"][0]["MessageId"] == "CGEN1006":
module.fail_json(msg=DOMAIN_FAIL_MSG)
return
def check_mode_validation(module, loc_resp):
exist_config = {
"EnableKvmAccess": loc_resp["EnableKvmAccess"], "EnableChassisDirect": loc_resp["EnableChassisDirect"],
"EnableChassisPowerButton": loc_resp["EnableChassisPowerButton"],
"EnableLcdOverridePin": loc_resp["EnableLcdOverridePin"], "LcdAccess": loc_resp["LcdAccess"],
"LcdCustomString": loc_resp["LcdCustomString"], "LcdLanguage": loc_resp["LcdLanguage"]}
quick_sync = loc_resp["QuickSync"]
exist_quick_config = {
"QuickSyncAccess": quick_sync["QuickSyncAccess"], "TimeoutLimit": quick_sync["TimeoutLimit"],
"EnableInactivityTimeout": quick_sync["EnableInactivityTimeout"],
"TimeoutLimitUnit": quick_sync["TimeoutLimitUnit"],
"EnableReadAuthentication": quick_sync["EnableReadAuthentication"],
"EnableQuickSyncWifi": quick_sync["EnableQuickSyncWifi"]}
req_config, req_quick_config, payload = {}, {}, {}
lcd_options, chassis_power = module.params.get("lcd"), module.params.get("chassis_power_button")
if loc_resp["LcdPresence"] == "Present" and lcd_options is not None:
req_config["LcdCustomString"] = lcd_options.get("user_defined")
req_config["LcdAccess"] = lcd_options.get("lcd_access")
req_config["LcdLanguage"] = lcd_options.get("lcd_language")
req_config["EnableKvmAccess"] = module.params.get("enable_kvm_access")
req_config["EnableChassisDirect"] = module.params.get("enable_chassis_direct_access")
if chassis_power is not None:
power_button = chassis_power["enable_chassis_power_button"]
if power_button is False:
chassis_pin = chassis_power.get("enable_lcd_override_pin")
if chassis_pin is True:
exist_config["LcdOverridePin"] = loc_resp["LcdOverridePin"]
req_config["LcdOverridePin"] = chassis_power["disabled_button_lcd_override_pin"]
req_config["EnableLcdOverridePin"] = chassis_pin
req_config["EnableChassisPowerButton"] = power_button
q_sync = module.params.get("quick_sync")
if q_sync is not None and loc_resp["QuickSync"]["QuickSyncHardware"] == "Present":
req_quick_config["QuickSyncAccess"] = q_sync.get("quick_sync_access")
req_quick_config["EnableReadAuthentication"] = q_sync.get("enable_read_authentication")
req_quick_config["EnableQuickSyncWifi"] = q_sync.get("enable_quick_sync_wifi")
if q_sync.get("enable_inactivity_timeout") is True:
time_limit, time_unit = q_sync.get("timeout_limit"), q_sync.get("timeout_limit_unit")
if q_sync.get("timeout_limit_unit") == "MINUTES":
time_limit, time_unit = time_limit * 60, "SECONDS"
req_quick_config["TimeoutLimit"] = time_limit
req_quick_config["TimeoutLimitUnit"] = time_unit
req_quick_config["EnableInactivityTimeout"] = q_sync.get("enable_inactivity_timeout")
req_config = dict([(k, v) for k, v in req_config.items() if v is not None])
req_quick_config = dict([(k, v) for k, v in req_quick_config.items() if v is not None])
cloned_req_config = copy.deepcopy(exist_config)
cloned_req_config.update(req_config)
cloned_req_quick_config = copy.deepcopy(exist_quick_config)
cloned_req_quick_config.update(req_quick_config)
diff_changes = [bool(set(exist_config.items()) ^ set(cloned_req_config.items())) or
bool(set(exist_quick_config.items()) ^ set(cloned_req_quick_config.items()))]
if module.check_mode and any(diff_changes) is True:
module.exit_json(msg=CHANGES_FOUND, changed=True)
elif (module.check_mode and all(diff_changes) is False) or \
(not module.check_mode and all(diff_changes) is False):
module.exit_json(msg=NO_CHANGES_FOUND)
payload.update(cloned_req_config)
payload["QuickSync"] = cloned_req_quick_config
payload["QuickSync"]["QuickSyncHardware"] = loc_resp["QuickSync"]["QuickSyncHardware"]
payload["SettingType"] = "LocalAccessConfiguration"
payload["LcdPresence"] = loc_resp["LcdPresence"]
return payload
def get_device_details(rest_obj, module):
device_id, tag = module.params.get("device_id"), module.params.get("device_service_tag")
if device_id is None and tag is None:
key, value = get_chassis_device(module, rest_obj)
device_id = value
else:
key, value = ("Id", device_id) if device_id is not None else ("DeviceServiceTag", tag)
param_value = "{0} eq {1}".format(key, value) if key == "Id" else "{0} eq '{1}'".format(key, value)
resp = rest_obj.invoke_request("GET", DEVICE_URI, query_param={"$filter": param_value})
resp_data = resp.json_data.get("value")
rename_key = "id" if key == "Id" else "service tag"
if not resp_data:
module.fail_json(msg=DEVICE_FAIL_MSG.format(rename_key, value))
if key == "DeviceServiceTag" and resp_data[0]["DeviceServiceTag"] == tag:
device_id = resp_data[0]["Id"]
elif key == "Id" and resp_data[0]["Id"] == device_id:
device_id = resp_data[0]["Id"]
else:
module.fail_json(msg=DEVICE_FAIL_MSG.format(rename_key, value))
try:
loc_resp = rest_obj.invoke_request("GET", LAC_API.format(device_id))
except HTTPError as err:
err_message = json.load(err)
error_msg = err_message.get('error', {}).get('@Message.ExtendedInfo')
if error_msg and error_msg[0].get("MessageId") == "CGEN1004":
module.fail_json(msg=LAC_FAIL_MSG)
else:
payload = check_mode_validation(module, loc_resp.json_data)
final_resp = rest_obj.invoke_request("PUT", LAC_API.format(device_id), data=payload)
return final_resp
def main():
chassis_power = {
"enable_chassis_power_button": {"type": "bool", "required": True},
"enable_lcd_override_pin": {"type": "bool", "required": False},
"disabled_button_lcd_override_pin": {"type": "int", "required": False, "no_log": True}}
quick_sync_options = {
"quick_sync_access": {"type": "str", "required": False, "choices": ["DISABLED", "READ_ONLY", "READ_WRITE"]},
"enable_inactivity_timeout": {"type": "bool", "required": False},
"timeout_limit": {"type": "int", "required": False},
"timeout_limit_unit": {"type": "str", "required": False, "choices": ["SECONDS", "MINUTES"]},
"enable_read_authentication": {"type": "bool", "required": False},
"enable_quick_sync_wifi": {"type": "bool", "required": False}}
lcd_options = {
"lcd_access": {"type": "str", "required": False, "choices": ["VIEW_AND_MODIFY", "VIEW_ONLY", "DISABLED"]},
"user_defined": {"type": "str", "required": False},
"lcd_language": {"type": "str", "required": False}}
specs = {
"device_id": {"required": False, "type": "int"},
"device_service_tag": {"required": False, "type": "str"},
"enable_kvm_access": {"required": False, "type": "bool"},
"enable_chassis_direct_access": {"required": False, "type": "bool"},
"chassis_power_button": {
"required": False, "type": "dict", "options": chassis_power,
"required_if": [["enable_lcd_override_pin", True, ("disabled_button_lcd_override_pin",)]],
},
"quick_sync": {
"required": False, "type": "dict", "options": quick_sync_options,
"required_if": [["enable_inactivity_timeout", True, ("timeout_limit", "timeout_limit_unit")]]
},
"lcd": {
"required": False, "type": "dict", "options": lcd_options,
},
}
specs.update(ome_auth_params)
module = AnsibleModule(
argument_spec=specs,
mutually_exclusive=[('device_id', 'device_service_tag')],
required_one_of=[["enable_kvm_access", "enable_chassis_direct_access",
"chassis_power_button", "quick_sync", "lcd"]],
supports_check_mode=True,
)
try:
if not any([module.params.get("chassis_power_button"), module.params.get("quick_sync"),
module.params.get("lcd"), module.params.get("enable_kvm_access") is not None,
module.params.get("enable_chassis_direct_access") is not None]):
module.fail_json(msg=CONFIG_FAIL_MSG)
with RestOME(module.params, req_session=True) as rest_obj:
check_domain_service(module, rest_obj)
resp = get_device_details(rest_obj, module)
resp_data = resp.json_data
quick_sync = module.params.get("quick_sync")
if quick_sync is not None and quick_sync.get("enable_inactivity_timeout") is True and \
quick_sync.get("timeout_limit_unit") == "MINUTES":
resp_data["QuickSync"]["TimeoutLimit"] = int(resp_data["QuickSync"]["TimeoutLimit"] / 60)
resp_data["QuickSync"]["TimeoutLimitUnit"] = "MINUTES"
module.exit_json(msg=SUCCESS_MSG, local_access_settings=resp_data, changed=True)
except HTTPError as err:
module.fail_json(msg=str(err), error_info=json.load(err))
except URLError as err:
module.exit_json(msg=str(err), unreachable=True)
except (IOError, ValueError, SSLError, TypeError, ConnectionError, AttributeError, IndexError, KeyError, OSError) as err:
module.fail_json(msg=str(err))
if __name__ == '__main__':